RCE, when working in conjunction with solar batteries (SB) and storage batteries (SB), provides:
1) on-board equipment (BE) with stabilized constant voltage of 27 V;
2) BE with unstabilized constant voltage (24-33) V;
3) battery charge with limitation of the maximum charging current, maximum voltage depending on temperature;
4) battery discharge with limitation of the maximum discharge current, minimum voltage depending on temperature;
5) telemetric control of the parameters of power supply units, the formation and delivery of information arrays via wired circuits about the state of the parameters of power supply units during normal operation;
6) receiving and executing commands;
7) electrical tests from both ground and standard power sources.
The RCE includes:
• A set of chargers, consisting of several identical channels of chargers (CH);
• Power cross-module with power switching units (PSU) of unstabilized bus channels (BC) with load current limitation;
• Voltage stabilizer 27 V with a power switching unit (PSU) of stabilized bus channels (BS);
• RCE control system.
Structurally, the RCE is made in the form of a monoblock made of modules, the number of which varies depending on the average power consumed by the BE in the shade, the average power consumed by the BE in the illuminated area, and the peak power. From these parameters, the number and type of memory channels and discharge device channels, as well as the number of SB panels and AB configuration are selected. The upper peak power scaling limit for a regulated 27 V rail is 1,500 W.
The RCE control system is universal and consists of two microcontrollers operating in hot standby. The volume of peripheral devices for measuring analog parameters (multiplexers and ADCs) and issuing control commands (registers) corresponds to the most powerful EPS.
The power line of the memory is tied to the area of the SB based on three-stage GaAs PEC and has the form:
1) for the area of the SB panel up to 0.5 m2 ZU200 (rated power 200 W);
2) for the area of the SB panel (0.5-0.75) m2 ZU300 (rated power 300 W);
3) for the area of the SB panel (0.75-1) m2 ZU400 (rated power 400 W);
4) for the area of the SB panel (1-1.5) m2 ZU600 (rated power 600 W).
The storage battery used in the EPS must have a voltage range of (24-33) V, the accumulator capacity is increased by increasing the number of parallel connected strings. The capacity of the battery depends on the depth of the battery discharge, the duration of the shadow section of the orbit and the average power consumed by the battery in the shadow.
Non-stabilized bus channels are separate modules and can be expanded depending on the platform requirements.
Own development of the company according to company standards, compatible with ECSS recommendations, relatively low cost, modular scalable structure; availability of stabilized and unstabilized power rails 27V; use of unified electrical, information and mechanical interfaces; at the beginning of 2022, the GEM cycle will take place.
|
Parameters |
|
|
Dimensions, mm |
306 х 161 х 140 (without fasteners) |
|
Mass, kg |
7 |
|
Power voltage, V |
22 — 34 |
|
Power consumption, Wt |
10 |
|
Duplicated interfaces |
CAN2B, RS485, SpaceWire |
|
Redundant galvanically separated stabilized subscriber power bus |
27 В, ECSS-E-ST-20-20C |
|
Redundant unstabilized subscriber power bus |
27 В, ECSS-E-ST-20-20C |